Release date: 2017-02-21
Enhancements
Ordering
- Order confirmation e-mail has been updated to provide a reminder on payment recurrence.
Systems
- A new option to display the subordinates of a system has been added to System dashboards. Clicking on the Vault icon will open up a Trend Log Viewer containing only the subordinates of the System.
Vault
- When Importing Trend Logs, seconds are now optional in the timestamp of the imported data set. The imported data will then have a timestamp containing :00 for the seconds.
- Imported Trend Log data can now be formatted in the following variants:
- MM/DD/YYYY hh:mm
- YYYY-MM-DD hh:mm
- YYYY-MM-DD hh:mm:ss (ISO)
Community Library
- 15 new Rule Templates (including FDD and Energy analytics) have been added to the CopperTree Community Library.
- Determine if consumption meter has failed
- Determine if temperature sensor is faulty
- Determine if CCV is open while OAT is lower than threshold, and HCV or Steam Control Valve is open
- Determine if Damper (MAD, OAD, RAD, VAV Damper) Signal is Modulating at an Abnormal Rate
- Determine if free cooling could be used for AHU operation
- Determine if mixed air damper (MAD) control could be optimized during heating season
- Determine if mode has not changed at least once during the course of a week
- Determine if Cooling Tower Fan is Running when Bypass Valve is Open
- Monitor bypass valve position and flow measured at the cooling tower, and determine if flow is minimum when bypass valve is open
- Determine if two units that should be staged are turned ON at the same time, without sufficient delay
- Determine if unit is running for extended period of time
- Determine if there is no noticeable decrease in electrical load during unoccupied hours
- Determine if unit heaters are operating when not required
- Convert energy savings to reduction in CO2 emissions (electrical)
- Calculate kW/ton and Coefficient of Performance for Water Cooled Chillers (Imperial)
Bug Fixes
Administration
- The Energy Star property ID in a Building profile can now be edited using FireFox.
- Non-admin group users can again add pages to their Favorites.
Energy
- Energy Views can again be viewed using a custom date range.
Fault Detection
- Hovering over a Trend Log link will no longer show Undefined if the monitored object is not defined.
Reporting
- Setpoints in Manual and Equipment in Hand reports will now display the complete object reference including device number for objects with issues.
- Changing the date range of any saved report will now succeed.